Operating Manual
and Users Guide
S2000 Miniature Fiber Optic
Spectrometers and Accessories
Offices: East Coast
380 Main Street, Dunedin, Fla., USA
727.733.2447
727.733.3962 Fax
8:30 a.m.-6 p.m. EST
West Coast
5190 Golden Foothill Parkway, El Dorado Hills, Calif., USA
916.939-4300
916.939.4307 Fax
Noon-9 p.m. EST
Ocean Optics B.V. (Europe)
Nieuwgraaf 108 G, 6921 RK DUIVEN, The Netherlands
31-(0)26-3190500
31-(0)26-3190505 Fax
E-mail: [email protected] (general sales inquiries)
Info@OceanOpticsBV.com (for sales questions in Europe)
[email protected] (for questions about orders)
T[email protected] (for technical support)
For all your photonice needs, visit:
OceanOptics.com
122800
Vue de la page 0
1 2 3 4 5 6 ... 111 112

Résumé du contenu

Page 1 - Operating Manual

Operating Manualand User’s GuideS2000 Miniature Fiber Optic Spectrometers and AccessoriesOffices: East Coast380 Main Street, Dunedin, Fla., USA727.733

Page 2 - Limit of Liability

Configure Data Acquisition Dialog Box Finally, select Spectrum | Configure Data Acquisition from the menu to open the Configure Data Acquisitiondialog

Page 3 - Table of Contents

Base Address Settings for the ADC1000 and PC2000 To change the Base Address settings on the ADC1000 and PC2000, see the bank of switches on the A/D bo

Page 4

Interrupt Request Settings for the ADC1000 and PC2000 To change the IRQ settings on the ADC1000 and PC2000, see the bank of switches on the A/D board:

Page 5 - Introduction

Appendix B: Adjusting the Focus for CollimatingLenses In order to obtain accurate data, the light entering and exiting a sample by means of a fiber/co

Page 6 - In This Manual

Appendix C: Calibrating the Wavelength of theSpectrometer The following describes how to calibrate the wavelength of your spectrometer. Though each sp

Page 7 - Upgrades

4. Now you are ready to calculate the wavelength calibration coefficients.In your spreadsheet program, find thefunctions to perform linear regressions

Page 8 - Quick Start

Appendix D: S2000 Pin-outs and JumpersThe average user would not normally need to know about the interconnect scheme of the S2000, as the cablessuppli

Page 9

Appendix D- 106 -J2 Pin DB-15 (Female) Description1 Single StrobeTTL output signal used to pulse a strobe that is high at the start of eachintegration

Page 10 - Reflection Setup

Continuous Strobe RateThe continuous strobe rate is controlled by the A/D converter frequency input to the spectrometer and the positionof a jumper in

Page 11 - S2000 Spectrometers

Appendix E: PC2000 Pin-outs and JumpersThe average user would not normally need to know about the interconnect scheme of the S2000, as thecables suppl

Page 12 - S2000 Specifications

Appendix F: External Triggering Our S2000 and S1024DW Spectrometers, when used withOOIBase32 Spectrometer Operating Software, provide fourmethods of a

Page 13 - S2000 Board Layout

S2000 Miniature Fiber Optic SpectrometersOur second-generation miniature fiber opticspectrometer, the S2000, couples a low-cost,high-performance 2048-

Page 14 - A/D Converters

source to supply the voltage, as it is based on a referenced ground and your reference may be different fromours. Using Pin 3 to supply voltage ensure

Page 15 - ADC500 ISA-bus A/D Converter

Configure Data Acquisition from the menu.4. Select Spectrum | Configure Data Acquisition from the menu. Choose the External Trigger page and selectSyn

Page 16 - Install OOIBase32

4. Once you have selected the integration time, note the configuration of the pins in theJumper Block 4 column of the chart.5. Remove your spectromete

Page 17 - Run OOIBase32

S2000 Specifications S2000 Miniature Fiber Optic Spectrometers-12-Absolute Maximum RatingsVCC+ 5.5 VDCVoltage on any pin VCC + 0.2 VDCPhysical Specifi

Page 18 - Specifications

S2000 Board Layout H1 Header Block connecting analog signals from slave spectrometer channel(s) to the Master spectrometer channelH2 Header Block cont

Page 19

A/D ConvertersThis section covers the basic installation instructions for our A/Dconverters: ADC500, ADC1000 (and PC2000), SAD500, and DAQ700.Because

Page 20 - Install the ADC1000 or PC2000

ADC500 ISA-bus A/D ConverterThe ADC500 ISA-BUS A/D CONVERTER is a 12-bit, 8-channel ISA-bus analog-to-digital converter card thatconnects our spectrom

Page 21

Windows NT Users:Find Available Base Address and IRQ Settings1. Go to Start | Programs | Administrative Tools (Common) | Windows NT Diagnostics.2. In

Page 22

Run OOIBase32After you restart your computer, navigate to the OOIBase32 icon and select it. The first time you run OOIBase32after installation, you mu

Page 23 - SAD500 Serial Port Interface

Spectrometer Configuration Dialog BoxNow that OOIBase32 is running, you need to configure your system. Select Spectrometer | Configure from themenu. G

Page 24 - Configure Hardware Dialog Box

ADC1000 ISA-bus A/D Converter (and PC2000)The ADC1000 ISA-BUS A/D CONVERTER is a 12-bit, 8-channel, single-ended A/D card that connects ourspectromete

Page 25 - Troubleshooting

Copyright © 2000 Ocean Optics, Inc.All rights reserved. No part of this publication may be reproduced or transmittedin any form or by any means, elect

Page 26 - DAQ-700 PCMCIA A/D Converter

Windows NT Users:Find Available Base Address and IRQ Settings1. Go to Start | Programs | Administrative Tools (Common) | Windows NT Diagnostics.2. In

Page 27 - Configure the DAQ-700

Run OOIBase32After you restart your computer, navigate to the OOIBase32 icon and select it. The first time you run OOIBase32after installation, you mu

Page 28 - Find the IRQ and I/O Range

Spectrometer Configuration Dialog BoxNow that OOIBase32 is running, you need to configure your system. Select Spectrometer | Configure from themenu. G

Page 29

SAD500 Serial Port InterfaceThe SAD500 SERIAL PORT INTERFACE is a microprocessor-controlled A/D converter for serial port connection orstand-alone ope

Page 30

Configure Hardware Dialog BoxNext, the Configure Hardware dialog box opens. Theparameters in this dialog box are usually set only once -- whenOOIBase3

Page 31

Save the spectrometer configuration file by choosing Spectrometer | Save Configuration As from the OOIBase32menu. You can rename the file or use the d

Page 32 - OOIBase OOIBase32

DAQ-700 PCMCIA A/D ConverterThe DAQ-700 PCMCIA A/D CONVERTER is a 12-bit analog-to-digital converter card that connects our spectrometersto notebook P

Page 33 - Light Sources

For Windows 95/98 Users:Configure the DAQ-7001. If you hear the “happy” sound, click Start, and select Settings | Control Panel.2. Double-click the Sy

Page 34 - Setting Up the MINI-D2T

8. While making this change, notice the Conflict information area at the bottom. Make sure you choose a value thatsays No devices are conflicting. If

Page 35 - Replacing the Bulbs

Run OOIBase32After you restart your computer, navigate to the OOIBase32 icon and select it. The very first time you runOOIBase32 after installation, y

Page 36 - Light Sources: D-1000

Table of ContentsIntroduction ...

Page 37 - Bulb Replacement

Spectrometer Configuration Dialog BoxNow that OOIBase32 is running, you need to configure your system. Select Spectrometer | Configure from themenu. G

Page 38 - Light Sources: DT-1000

OOIBase32 Spectrometer Operating Software OOIBASE32 SPECTROMETER OPERATING SOFTWARE is our next generation of operating software for all OceanOptics s

Page 39

Other advanced features provide you with several data collection options. You have the ability to independentlystore and retrieve dark, reference, sam

Page 40

Light SourcesOcean Optics light sources provide illumination and excitation in the UV, VIS or Shortwave NIR range forabsorbance, reflection and fluore

Page 41 - Using the Filter Slot

MINI-D2T Miniature Deuterium Tungsten Light SourceThe MINI-D2T MINIATURE DEUTERIUM TUNGSTEN LIGHT SOURCE combines the continuous spectrum of an RF-cou

Page 42 - Spectral Output

4. When you want to control the MINI-D2T through OOIBase32 Spectrometer Operating Software, select ordeselect the Strobe Enable box in the Acquisition

Page 43 - PX-2 Pulsed Xenon Lamp

D-1000 Deuterium Light Source The D-1000 DEUTERIUM LIGHT SOURCE is a high-output, high stability fiber optic light source optimized for theUV. The D-1

Page 44 - Light Sources: PX-2

8. Lift up the black protective shutter and disconnect your optical fiber from the SMA connector.9. Replace the red plastic cap over the SMA connector

Page 45 - (with a min. value of 24 ms)

DT-1000 Deuterium Tungsten Halogen Light SourceThe DT-1000 DEUTERIUM TUNGSTEN HALOGEN LIGHT SOURCE combines the continuous spectrum of adeuterium UV l

Page 46 - Jumper Block 2 (JP2)

Operating the Deuterium Source1. To power the deuterium lamp, push in the UV Start button located on the front panel. This white button turnson the de

Page 47 - Using JP3 on the S2000

Fiber Optic Probes and Accessories...83R200 Reflection Probes...

Page 48 - Setting the Integration Time

4. Gently grip the top of the bulb and pull it away from the cylindrical unit. Discard the bulb.5. Insert the new bulb into the top of the cylinder, b

Page 49 - Light Sources: HG-1

LS-1 Tungsten Halogen Light Source The LS-1 TUNGSTEN HALOGEN LIGHT SOURCE is a versatile, white-light lamp utilized for the VIS-Shortwave NIR(360 nm-2

Page 50

4. Locate the two set screws at the back of the lamp, one above each back leg. These two screws keep the twohalves of the lamp together. Remove the tw

Page 51

PX-2 Pulsed Xenon Lamp The PX-2 PULSED XENON LAMP is a high flash rate, short-arc xenon lamp for applications involving absorbance,reflection, fluores

Page 52 - Light Sources: LS-1-CAL

operating software. To achieve a constant number of flashes per integration cycle, the integration time must be amultiple of those shown in the follow

Page 53

LS-450 Blue LED Pulsed Light Source The LS-450 BLUE LED PULSED LIGHT SOURCE is a compact, low-cost light-emitting diode that produces pulsed orcontinu

Page 54 - Sampling Chambers

R-LS-450 Rack-mount Blue LED Pulsed Light Source The R-LS-450 BLUE LED PULSED LIGHT SOURCE is a compact, low-cost light-emitting diode that produces p

Page 55 - Parts Included

Jumper Block 3 (JP3)There are two sets of pins in JP3. The jumper position here determines the source of control for the R-LS-450:manual or remote con

Page 56

You can control the pulses per second of the R-LS-450 through the Flash Delay function in the OOIBase32software if:" The switch is turned to puls

Page 57

HG-1 Mercury Argon Calibration Source The HG-1 MERCURY ARGON CALIBRATION SOURCE is a wavelength calibration source for UV-VIS-ShortwaveNIR spectrophot

Page 58 - CUV-ALL 4-way Cuvette Holder

IntroductionOcean Optics miniature fiber optic spectrometers and accessories have revolutionized the analyticalinstrumentation market by dramatically

Page 59

1. After placing OOIBase32 into Scope Mode, take a spectrum of your light source. Adjust the integration timeuntil there are several peaks on the scre

Page 60

6. The numbers of importance are indicated in the above figure. You will need to record the Intercept as well asthe First, Second, and Third Coefficie

Page 61

LS-1-CAL Calibrated Light Source The LS-1-CAL CALIBRATED LIGHT SOURCE for the VIS-Shortwave NIR (300-1050 nm) is a tungsten halogenlight source that p

Page 62

6. Find the on/off switch on the back of the lamp and turn the lamp on.7. Let the lamp warm up for at least 15 minutes before using.8. Insert the disk

Page 63

Sampling Chambers Ocean Optics offers a comprehensive line of compact, low-cost sampling chambers for a variety of UV-VIS-Shortwave NIR applications.

Page 64

CUV-UV, CUV-VIS Cuvette Holders The CUV-UV and CUV-VIS CUVETTE HOLDERS for 1-cm path length cuvettes couple via SMA-terminated opticalfibers to our sp

Page 65

Specifications* Though the VIS-NIR lens is optimized for use to 2 µm, it can be configured to "see" only to 1100 nm with ourS2000 spectromet

Page 66 - Setting Up the ISS-UV-VIS

CUV-UV-10, CUV-VIS-10 Cuvette Holders The CUV-UV-10 and CUV-VIS-10 CUVETTE HOLDERS for 10-cm cuvettes couple to our spectrometers and lightsources to

Page 67

CUV-ALL 4-way Cuvette Holder The CUV-ALL 4-WAY CUVETTE HOLDER for 1-cm path length cuvettes has four collimating lenses that couple tooptical fibers,

Page 68

Installing Filters1. Loosen the filter clamping screw with the provided screwdriver.2. Insert the filter into the filter slot. The filter slot can acc

Page 69

OOIBase32 Spectrometer Operating Software is our next generation of operating software for all Ocean Opticsspectrometers. OOIBase32 is a 32-bit, user-

Page 70 - LPC Long Pass Flow Cells

CUV-FL-DA Direct Attach Cuvette Holder The CUV-FL-DA DIRECT ATTACH CUVETTE HOLDER attaches directly to our light sources and couples viaSMA-terminated

Page 71

SpecificationsSampling Chambers: CUV-FL-DA-61-Path length: 1 cmDimensions: 1.4” x 1.4” x 1.0” (L x W x H)Material: Black anodized aluminumHole diamete

Page 72

ISS Integrated Sampling SystemThe ISS INTEGRATED SAMPLING SYSTEM is a fully integrated 1-cm cuvette holder and tungsten halogen light source.It couple

Page 73

8. Tighten the set screw on the bottom of the lamp.9. Close the two halves without pinching the wires. Replace the two screws at the back of the lamp.

Page 74 - Sampling Optics

ISS-2 Integrated Sampling SystemThe ISS-2 INTEGRATED SAMPLING SYSTEM is a fully integrated 1-cm cuvette holder and tungsten halogen lightsource. It co

Page 75 - Application Tips

6. Gently separate the two halves of the lamp and pull the bulb out of its housing. 7. Detach the wire and socket from the lamp leads. Remove bulb uni

Page 76

ISS-UV-VIS Integrated Sampling SystemThe ISS-UV-VIS INTEGRATED SAMPLING SYSTEM is a combination of a RF deuterium source with a tungstenbulb connected

Page 77 - 74-OPM Optical Post Mount

Operating the ISS-UV-VIS through Software1. Connect the 15-pin accessory cable from the spectrometer to the ISS-UV-VIS.2. Find the switch on the back

Page 78

FHS-UV and FHS-VIS In-line Filter HoldersThe FHS-UV and FHS-VIS IN-LINE FILTER HOLDERS are low-cost spectrophotometric accessories for fast,convenient

Page 79

SpecificationsSampling Chambers: FHS-UV, FHS-VIS-69-FHS-VIS Collimating lenses (VIS-NIR):BK 7 glass (~360 nm - 2 µm*)5 mm diameterf/2FHS-UV Collimatin

Page 80

Packing List A packing list comes with your order. It is located inside a plastic bag attached to the outside of the shipment box.The invoice is maile

Page 81 - ISP-REF Integrating Sphere

LPC Long Pass Flow CellsLPC LONG PASS FLOW CELLS from Ocean Optics couple to the company's high-sensitivity fiber opticspectrometers and compact

Page 82

Assessing if the LPC is Free of ParticlesFluids need to be relatively particle-free. Particles larger than 20 µm can be trapped inside the tubing and

Page 83 - T300-RT-UV/VIS

CUV-CCE Electrophoresis Sample CellThe CUV-CCE ELECTROPHORESIS SAMPLE CELL for chromatography and capillary electrophoresis is anoptical fixture for m

Page 84 - R200 Reflection Probes

Checking the Alignment1. With the spectrometer running, observe the signal inScope Mode. When the optical window is properlypositioned, you can see a

Page 85 - RPH-1 Reflection Probe Holder

Sampling Optics Ocean Optics offers numerous spectroscopic accessories. A short description for each accessory featured in thismanual is listed below.

Page 86 - Caution!

74-UV, 74-VIS Collimating Lenses In order to obtain accurate data, the light entering the sample and the light collected after exiting the sample must

Page 87

74-90-UV Right Angle Reflector The 74-90-UV RIGHT ANGLE REFLECTOR is a 3/8-24 threaded black anodized aluminum assembly for mountingcollimating lenses

Page 88

74-OPM Optical Post Mount The 74-OPM OPTICAL POST MOUNT is a 3/8-24 threaded black anodized aluminum assembly used for mountingcollimating lenses on b

Page 89 - Optical Fiber Assemblies

74-ACH Adjustable Collimating Lens Holder The 74-ACH ADJUSTABLE COLLIMATING LENS HOLDER is a versatile assembly for mounting lenses at multiplepositio

Page 90 - Optical Fiber Color Codes

FVA-UV Fiber Optic Variable Attenuator The FVA-UV FIBER OPTIC VARIABLE ATTENUATOR is an opto-mechanical device that controls the amount of lightenteri

Page 91 - Experiment Tutorial

Quick StartThe S2000 is easy to set up, allowing the user to start collecting data within minutes. The three pages in thissection provide brief instru

Page 92 - Absorbance Experiments

WS-1 Diffuse Reflectance Standard The WS-1 DIFFUSE REFLECTANCE STANDARD is a compact physical standard for use in performing diffusereflectance measur

Page 93 - Transmission Experiments

ISP-REF Integrating Sphere The ISP-REF INTEGRATING SPHERE is an illuminated sampling optic that couples via optical fiber to Ocean Opticsminiature fib

Page 94 - Reflection Experiments

FOIS-1 Fiber Optic Integrating Sphere The FOIS-1 FIBER OPTIC INTEGRATING SPHERE is a sampling optic that accepts light energy through its 0.375"i

Page 95

Fiber Optic Probes and Accessories Ocean Optics fiber optic probes couple to our miniature fiber optic spectrometers and light sources to create a var

Page 96 - Time Acquisition Experiments

R200 Reflection Probes R200 REFLECTION PROBES couple to Ocean Optics miniature fiber optic spectrometers and light sources to createsmall-footprint op

Page 97

RPH-1 Reflection Probe HolderThe RPH-1 REFLECTION PROBE HOLDER is an anodized aluminum platform with machined holes at 45° and 90°to hold our R200 Ref

Page 98

T300-RT-UV-VIS Transmission Dip ProbeThe T300-RT-UV/VIS TRANSMISSION DIP PROBE couples to our spectrometers and light sources to create small-footprin

Page 99

CC-3 Cosine-corrected Irradiance Probes The CC-3 COSINE-CORRECTED IRRADIANCE PROBES are spectroradiometric sampling optics designed to collectradiatio

Page 100 - Appendix A

FL-400 Flame-resistant Fiber ProbeThe FL-400 FLAME-RESISTANT FIBER PROBE is a heat-resistant fiber optic probe that couples to Ocean Opticsminiature f

Page 101

Optical Fiber Assemblies Ocean Optics offers an extensive line of optical fibers and accessories -- including patch cords, bifurcatedassemblies, bushi

Page 102

4. Note these values. When you first run OOIBase32, you must enter these values in the “Configure Hardware”dialog box.If your A/D converter is the SAD

Page 103 - Spectrometer

Splice Bushings, Bulkhead Fittings Splice bushings are used to couple two SMA-terminated fibers together. Simply screw each fiber into the splicebushi

Page 104 - Appendix C

Experiment Tutorial Before you begin your experiment, double-check that you have correctly installed your A/D converter, installedthe operating softwa

Page 105

Absorbance Experiments Absorbance spectra are a measure of how much light is absorbed by a sample. For most samples, absorbance islinearly related to

Page 106 - Appendix D

Transmission Experiments Transmission is the percentage of energy passing through a system relative to the amount that passes through thereference. Tr

Page 107 - Continuous Strobe Rate

Reflection Experiments Reflection is the return of radiation by a surface, without a change in wavelength. The reflection may be:" Specular, in w

Page 108 - H1 Header Block

Relative Irradiance Experiments Irradiance is the amount of energy at each wavelength from a radiant sample. In relative terms, it is the fractionof e

Page 109 - External Software Trigger

Time Acquisition Experiments Our OOIBase32 Spectrometer Operating Software allows you to perform time acquisition experiments. Timeacquisition experim

Page 110 - Appendix F

7. Access the Time AcquisitionConfiguration dialog box by selectingTime Acquisition | Configure |Configure Acquisition from the menu." Enable Str

Page 111 - External Hardware Trigger

Appendix A: Changing the A/D Converter SettingsBase Address Settings for the ADC500 To change the Base Address settings on the ADC500 board, see the b

Page 112

Interrupt Request Settings for the ADC500 To change the IRQ settings on the ADC500 board, see the bank of 4 dip switches labeled SW2. In the defaultse