USB2000+ Fiber Optic SpectrometerInstallation and Operation ManualDocument Number 270-00000-000-02-201107Offices: Ocean Optics, Inc. World Headquarter
1: Introduction4 270-00000-000-02-201107 Wavelength Calibration Data SheetEach spectrometer is shipped with a Wavelength Calibration Data Sheet that
1: Introduction270-00000-000- 02-201107 5
270-00000-000-02-201107 6Chapter 2Installing the USB2000+OverviewYou must install the SpectraSuite software application prior to connecting the USB200
2: Installing the USB2000+270-00000-000- 02-201107 7If you have followed the previous steps and started SpectraSuite, the spectrometer is already acqu
2: Installing the USB2000+8 270-00000-000-02-201107the graph. If you allow light into the spectrometer, the graph trace should rise with increasing li
270-00000-000-02-201107 9Chapter 3TroubleshootingOverviewThe following sections contain information on troubleshooting issues you may encounter when u
3: Troubleshooting10 270-00000-000-02-201107NoteImproperly installed USB devices can also appear under the Universal Serial Bus Controller option. Be
3: Troubleshooting270-00000-000- 02-201107 11Linux Operating SystemsFor Linux operating systems, all you need to do is install the SpectraSuite softwa
3: Troubleshooting12 270-00000-000-02-201107
270-00000-000-02-201107 13Appendix ACalibrating the Wavelength of the USB2000+OverviewThis appendix describes how to calibrate the wavelength of your
Additional Offices:Ocean Optics Asia 666 Gubei Road, Kirin Tower, Suite 601B, Changning District, Shanghai, PRC. 200336Phone 86.21.5206.8686Fax 86.
A: Calibrating the Wavelength of the USB2000+14 270-00000-000-02-201107Calibrating the SpectrometerPreparing for Calibration To recalibrate the wavele
A: Calibrating the Wavelength of the USB2000+270-00000-000- 02-201107 15True Wavelength (nm) Pixel # Pixel # 2Pixel # 3Predicted WavelengthDifference2
A: Calibrating the Wavelength of the USB2000+16 270-00000-000-02-2011077. Record the Intercept, as well as the First, Second, and Third Coefficients.
270-00000-000-02-201107 17Appendix BSpecificationsOverviewThis appendix contains information on spectrometer operation, specifications, and system com
B: Specifications18 270-00000-000-02-201107USB2000+ Components TableOcean Optics permanently secures all components in the USB2000+ at the time of man
B: Specifications270-00000-000- 02-201107 19USB2000+ SpecificationsThe following table provides specification information for the USB2000+. Specificat
B: Specifications20 270-00000-000-02-201107Accessory Connector PinoutThe USB2000+ features a 22-pin Accessory Connector, located on the front of the u
B: Specifications270-00000-000- 02-201107 21Pin # Function Input/Output Description5VINOutput USB specifications2 RS232 Tx OutputRS232 transmit signal
B: Specifications22 270-00000-000-02-201107
270-00000-000-02-201107 23IndexAaccessories, 4, 7accessory connectordiagram, 20pin definitions, 20pinout, 20additional equipment, 4Adobe Acrobat Reade
270-00000-000-02-201107 iTable of ContentsAbout This Manual...
Index24 270-00000-000-02-201107SSamplingSystem, 3Serial Port mode, 7service, ivsetup, 6shipment components, 3slit, 18SMA Connector, 18Software and Res
Table of Contentsii 270-00000-000-02-201107Chapter 3: Troubleshooting ...9Overview ...
270-00000-000-02-201107 iiiAbout This ManualDocument Purpose and Intended AudienceThis document provides the users of USB2000+ Spectrometers with inst
About This Manualiv 270-00000-000-02-201107 Detailed instructions for External Triggering for firmware versions below 3.0 are located at: http://www.
270-00000-000-02-201107 1Chapter 1IntroductionProduct OverviewThe USB2000+ Miniature Fiber Optic Spectrometer is a unique combination of technologies
1: Introduction2 270-00000-000-02-201107Features Sony ILX511 2048-element linear silicon CCD array detector Responsive from 200 to 1100 nm Sensitiv
1: Introduction270-00000-000- 02-201107 3SpectraSuite is a user-customizable, advanced acquisition and display program that provides a real-time inter